  1. Image 1 shows the siders sucked,, Sorry to be blunt. That panel is installed and cut wrong. Have them fix it,, There should be a 3/4 - 1 up first then there angle, Second picture shows they did not give a rats arse how they installed the gable. The angle is completely wrong.. I would venture to say that there are more then one of these miss cut angles.. As far as the profile on the corner. That is a preference not a error. They could have put a gable boot on it and made a 3d profile, instead they ran it into the soffitt on side of house. Now that is not 2" j-channel,, that is 1" and siding should be 1/4 short on both sides and be able to slide back and forth. What I am seeing is they were slacks and very unprofessional,, Im sorry you got that from them. As far as the soffitt vents on the gable ends,, there should be NONE only on the flats. On gable ends as shown you should have Gable vents. Hope you get this fixed,, it is more then cosmetic. Jason
×
×