Jump to content

Darren

Members
  • Posts

    947
  • Joined

  • Last visited

Personal Information

  • Location
    Basking Ridge NJ
  • Occupation
    Home Inspector

Recent Profile Visitors

The recent visitors block is disabled and is not being shown to other users.

Darren's Achievements

Member

Member (3/5)

3

Reputation

  1. John, Not from my client, but the insurance company is requiring a complete roof replacement because of missing granular.
  2. Inspected a roof back in March; here are some photos. What would you say about this roof?
  3. March 2018 meeting minutes from NJ Home Inspectors Advisory Board; Incoming Correspondence Nick Gromicko, Founder, InterNACHI RE: InterNACHI Marketing Program January 25, 2018 Mr. Gromicko responded to the Committee’s request for additional information regarding a proposed marketing program which would provide real estate agents with a complimentary prelisting inspection on homes for sale which could be uploaded to their on-line property listings. 3 Mr. Gromicko stated that this marketing program has not yet been launched. He further advised that he would address any further questions from the Committee regarding the program’s development and InterNACHI’s intentions if requested. Can someone explain the end game here?
  4. Here's what I found at yesterdays inspection. Some ugly, some not so ugly.
  5. In newer townhouses, I've seen where there is a 'clean-out' door about 18 inches below the dryer connection.
  6. Darren

    Oil Tank

    What, if anything would you say about this oil tank. The stain is just that, a stain, not wet.
  7. At the end of the 2nd article above, there is a link provided. Here's the one about venting; it's a cool video. http://www.elitesoft.com/pub/videos/gasvent/gasvent.htm
  8. Yes, they are allowed to be combined but certain rules do apply. Download Attachment: JB Column 1.pdf 68.84 KB Download Attachment: JB Column2.pdf 74.46 KB
  9. They were installed in the offices on the last school I did 2 years ago. Start-up and trouble shooting was a big problem. There were some internal control problems that took a long time to get parts from the factory. After the initial start-up difficulty, they seemed to be working fine; no call backs from the school.
  10. Darren

    Draft Hood

    What, if anything would you say about this? I've seen this installed where the opening is on the bottom at a rear venting unit, but not this. Thanks Click to Enlarge 57.01 KB
  11. Has anyone seen this before and what is the cause? House built in 1980. Click to Enlarge 45.97 KB
  12. Looks like the Edge Vent. http://www.airvent.com/products/intake- ... -edge-vent
  13. Apartments converted to condos. First photo shows FP main disconnect at meter room. Second photo is new sub panel. 30 amp service, No 4 wire feed, ground and neutral together. What would you guys write? Click to Enlarge 60.46 KB Click to Enlarge 49.72 KB
  14. I found these a couple of weeks ago where they replaced all the columns. Click to Enlarge 39.99 KB Click to Enlarge 28.89 KB
  15. I know we discussed this before, but I cant find it here or in the code books. Can a shower door open into the shower? Click to Enlarge 36.81 KB
×
×
  • Create New...