  1. 2005 was the first year that the instructions for Hardiplank specifically required an un-caulked 1/4" gap above horizontal flashing. First printing was in September 05 with an effective date December 05. Maintain a 1/4" clearance between James Hardie products and horizontal flashing (fig. 6). Click to Enlarge 15 KB Download Attachment: hardiplank install eff 12-05.pdf 604.71 KB
  2. patt

    CO Detectors

    Denny The CA State Fire Marshall maintains a list of approved CO devices for use in CA, you could check the specs of the different ones. http://osfm.fire.ca.gov/strucfireengine ... er_bml.php
  3. I would probably still check with your local authority, the interesting part of the verbiage in the CPC is "listed relief valve drain tube" and in the Zurn ICC-ES Listing PMG 1039 they don't specifically list it for relief valve drainage. 2010 CA Plumbing Code 608.5 Relief valves located inside a building shall be provided with a drain, not smaller than the relief valve outlet, of galvanized steel, hard-drawn copper piping and fittings, CPVC or listed relief valve drain tube with fittings that will not reduce the internal bore of the pipe or tubing (straight lengths as opposed to coils) and shall extend from the valve to the outside of the building, with the end of the pipe not more than two (2) feet (610 mm) nor less than six (6) inches (152 mm) above ground or the flood level of the area receiving the discharge and pointing downward. Such drains shall be permitted to terminate at other approved locations. Relief valve drains shall not terminate in a building's crawl space. No part of such drain pipe shall be trapped or subject to freezing. The terminal end of the drain pipe shall not be threaded. Download Attachment: ZURN PMG-1039.pdf 49.11?KB
  4. I know of one brand that states it can be used for the TPR drain. See page 23 of manual; http://www.zurn.com/images/pdf/zpm07199.pdf Download Attachment: ZURN TPR.JPG 107.26 KB
  5. The ESR number (ESR 1031) is viewable in the photograph, just look it by that. Download Attachment: ESR-1031.pdf 170.73 KB
  6. Decent article on sniffers, "Non Contact Voltage Testers". http://www.homeinspect2020.com/Articles.html
  7. John You basically have two types of plaster, gypsum and cement. Cement plaster is stucco. The Uniform Building Code required weeps back in their 1970 edition predating the requirements of both ASTM C1063 and C926, 1986 and 1981 respectively. If you are inspecting stucco I'd advised you to get both ASTM standards. I think Mike has the Masonry Veneer Manufacturers Association manual to the library, if not, go to their site and download. Download Attachment: UBC_weep_screed.pdf 123.97 KB
  8. Jim I don't have the link you wanted but I do have a reprint from NRCA that's similar. Download Attachment: Why 1-inch overlap works.pdf 48.55 KB
  9. Mark The only information I've seen is the APA OSB product guide that states that there are exterior rated OSB products. I believe the LP SmartSide products are OSB overlaid with a treated resin paper. The only OSB panels I see used as sheathing are rated Exposure 1. Download Attachment: APA OSB exposure classification.pdf 82.83 KB
  10. CPSC and HUD state that discolored wiring does not have to be replaced. http://www.aboutlawsuits.com/chinese-dr ... hud-16988/ http://www.cpsc.gov/cpscpub/prerel/prhtml11/11176.html
  11. Lower BTU rating?
  12. Some good info on "poria" and other fungi. Download Attachment: Poria.pdf 1555.4 KB
  13. The other way to look at is; not the degree of exposure but is it installed to manufacturers' installation instructions? For that I would let someone else bless the installation.
  14. The JLC article you posted. Middle of the 'Flexible Flashing Specifications' table, rubberized asphalt/aluminum foil...no limitation. Other designs using foil may be limited though. Marc The article was just an overview always stick with manufacturers specs.
  15. Foil face may not be unlimited, see my first post.
  16. Mark The Dupont Flashing Tape Product Data states "Cover within 120 days" Download Attachment: K-16752_FlashingTapePhysProp.pdf 73.93 KB
  17. Length of UV exposure is product specific. Protecto Wrap standard self-adhered flashing tape states 120 days maximum exposure, while their foil faced self-adhered flashing is rated for one year. Fortifibers' FortiFlash instructions state, exposure not to exceed 45 days. Edit: Found an old JLC article with good information. Download Attachment: JLC Flexible flashings.pdf 317.5 KB
  18. Individual shut off valves are still not required, only a main shut off is. Download Attachment: 24cfr3280.609.pdf 66.36 KB
  19. CA has amended the IRC/CRC section dealing with freezing. NFPA 13D allows the use of anti-freeze. The IRC (P2904) also allows the system to be designed to NFPA 13D. R313.3.2.3 Freezing areas. Piping shall be protected from freezing as required by the California Plumbing Code. Where sprinklers are required in areas that are subject to freezing, dry-sidewall or dry-pendent sprinklers extending from a nonfreezing area into a freezing area shall be, installed. Where fire sprinkler piping cannot be adequately protected against freezing, the system shall be designed and installed in accordance with NFPA 13D.
  20. Mark if you look at any amount of stucco, you really should have a copy of both C1063 and C926.
  21. See 7.1.4 IBC 2510.3 Installation. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. IRC R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063 and the provisions of this code. ASTM C 926 7. Application 7.1 General: 7.1.1 Portland cement plaster shall be applied by hand or machine to the nominal thickness specified in Table 1. 7.1.2 Plaster nominal thickness shall be measured from the back plane of the metal plaster base, exclusive of ribs or dimples, or from the face of the solid backing with or without metal plaster base, to the outer surface exclusive of texture variations. 7.1.3 Portland cement-based plaster shall be applied on furred metal plaster base when the surface of solid backing consists of gypsum board, gypsum plaster, wood, or rigid foam board-type products. NOTE 5—On horizontal ceiling supports or roof soffits protected by a drip edge, gypsum board products shall be permitted to be used as backing for metal base to receive portland cement plaster. 7.1.4 Separation shall be provided where plaster abuts dissimilar construction materials or openings. (See A2.1.4.) (A2.1.4 is for interior plaster.)
  22. ASTM C1063 - 06 1" minimum. 7.11.5 Foundation Weep Screed—Foundation weep screed shall be installed at the bottom of all steel or wood framed exterior walls to receive lath and plaster. Place the bottom edge of the foundation weep screed not less than 1 in. (25 mm) below the joint formed by the foundation and framing. The nose of the screed shall be placed not less than 4 in. (102 mm) above raw earth or 2 in. (51 mm) above paved surfaces. The weather resistive barrier and lath shall entirely cover the vertical attachment flange and terminate at the top edge of the nose or ground flange.
  23. Duro-Last notes in their product infomation that standing water will not effect their warranty. Click to Enlarge 22.7 KB
  24. That's most likely a two stage gas system. The half inch copper is higher pressure/volume and the inline regulator steps it down for final use.
×
×